# 专题跟踪 · 可靠性 · 2026-09-03 > 日期:2026-09-03(Asia/Shanghai)。对应卷宗 `topics/reliability.md`。SmartX 与 Arcfra 分列;RPO/RTO 保持厂商自称。 ## 摘要 - VCF 9.1 仍以 vSAN stretched + 独立 Witness 为站点双活主路径;Compute-only 拉伸文档写可不配 witness。管理域须先拉伸。HA isolation address 要指到 vSAN 网。 - SmartX 榫卯 6.3(2026-03-24):VM 级同步复制(厂商称 RPO=0)、拉伸双活门槛称降至 4 节点、SR-IOV/HCT/vGPU HA、CloudTower 管控 HA。选型文明确拉伸自动切换 vs 同步复制人工切换。 - Nutanix Metro/Sync 仍在 Ultimate/Adv Replication 墙后;NC2 AWS 上的 Metro 要用 Witness 事件驱动 NCM Playbook 改 TGW。 - HPE 9.0:拉伸与 2 节点 GFS2 共用 Distributed Worker 见证,且不能一证多用。VME 8.x HCI 布局仍是 ≥3 主机。 - NVIDIA Dynamo Snapshot(CRIU + cuda-checkpoint)与 Shadow Engine Failover 把推理恢复做成 K8s/CUDA 层,不是 hypervisor FT。vSphere 9.1 获 NVIDIA-Certified Hypervisor。ZStack ZLR 调研日未 GA。 ## 原文摘录 ### [Stretching vSAN Clusters in VMware Cloud Foundation](https://techdocs.broadcom.com/us/en/vmware-cis/vcf/vcf-9-0-and-later/9-1/building-your-private-cloud-infrastructure/stretching-clusters.html) - 来源:VCF 9.1 / Last Updated July 27, 2026 > You can stretch a vSAN cluster in a workload domain across two availability zones within a region. Both availability zones must contain an equal number of hosts to ensure failover in case any of the availability zones goes down. … The default management domain vSphere cluster must be stretched before a workload domain cluster can be stretched. … vSAN Compute Only clusters support a two-node configuration (one host per availability zone). A witness host is not required for this specific topology. ### [vSAN Stretched Cluster Guide](https://www.vmware.com/docs/vsan-stretched-cluster-guide) - 来源:VMware 文档(VCF 9.1 段) > VMware vSAN is fully integrated and supported with vSphere HA, and should be enabled on all vSAN clusters. … Since ESXi hosts will be equally divided across both sites in a stretched cluster, it is recommended that Admission Control be set to 50% for both memory and CPU. … one must change the isolation addresses … to the vSAN network to ensure that HA is testing against the network providing data … ### [榫卯超融合 6.3 发布](https://www.smartx.com/blog/2026/03/sunmao-6-3/) - 来源:SmartX 博客 2026-03-24 > 该版本在业内率先基于超融合架构提供同步复制容灾(RPO=0)及 RDMA 存储网络跨网卡高可用、SR-IOV 高可用等高性能业务连续性保障能力 … 虚拟机级同步复制实现 RPO=0:在已经具备拉伸集群双活能力的基础上,榫卯超融合 6.3 在国内率先提供以虚拟机为粒度的 RPO=0 原生同步复制能力。相比双活拉伸集群,同步复制无需对整个集群进行保护,可自动容忍容灾网络抖动 … 榫卯超融合 6.3 将跨站点双活集群的构建门槛由传统的 6 节点优化至 4 节点起步 … 榫卯超融合 6.3 还提供了 vGPU 高可用能力 ### [同步复制与拉伸集群双活选型对比](https://www.smartx.com/blog/2026/04/sunmao-6-3-dr-q004/) - 来源:SmartX 2026-04 > | 对比维度 | 拉伸集群双活 | 同步复制 | 保护粒度 | 整个集群 | 虚拟机级别 | RPO | RPO=0 | RPO=0 | 故障切换 | 自动切换 | 人工执行 | 网络要求 | 依赖稳定低延迟L2网络 | 支持跨L3网络,容忍一定延迟与抖动 | ### [同步复制 RPO=0 实现原理](https://www.smartx.com/blog/2026/04/sunmao-6-3-dr-q002/) - 来源:SmartX > 进入已同步状态后,所有写入同时作用于源端与目标端,且需在两端均完成后才返回成功,实现RPO=0。当网络抖动或短时中断时自动降级,源端业务写入不中断,网络恢复后自动同步至副本,确保最终一致性。 ### [AHV Metro on NC2 on AWS](https://www.nutanix.com/blog/design-overview-ahv-metro-on-nutanix-cloud-clusters-nc2-on-aws) - 来源:Nutanix 博客 > In NCM Intelligent Operations you need to create the playbook that will trigger Alert Policy - Automatic Failover triggered by Witness. … With communication down between the witness and AZ A and between AZ A and B the Automatic Failover triggered by Witness will be triggered executing our playbook. … If the DR site/sync destination is not reachable, automatic pause is done on source to ensure business continuity. ### [HPE VME 9 stretched / 2-node GFS2](https://community.hpe.com/t5/hpe-morpheus-vm-essentials/stretched-cluster-and-2-node-cluster-with-shared-storage-gfs2-v9/td-p/7268996) - 来源:HPE 社区(工程师回复) > stretched clusters and 2-node clusters do share the same basic architecture and the witness is the same Distributed Worker in both cases. … As for using the same witness for more than one cluster, this can't be done today ### [HVM clusters · VME 8.0.5](https://hpevm-docs.morpheusdata.com/en/8.0.5-vme/infrastructure/clusters/mvm.html) - 来源:HPE VM Docs > An HVM cluster using the hyperconverged infrastructure (HCI) Layout consists of at least three hosts. … With just one host it won’t be possible to migrate workloads between hosts or take advantage of automatic failover. ### [NVIDIA Dynamo Snapshot](https://developer.nvidia.com/blog/nvidia-dynamo-snapshot-fast-startup-for-inference-workloads-on-kubernetes/) - 来源:NVIDIA Technical Blog > NVIDIA Dynamo Snapshot introduces checkpoint/restore for AI inference workloads on Kubernetes … The approach combines CRIU for host state and cuda-checkpoint for GPU state, orchestrated by a privileged DaemonSet that writes artifacts to shared storage and restores them on the same or different nodes. … GMS uses the CUDA Virtual Memory Management (VMM) API to decouple large model weights from the inference worker’s process lifetime ### [Shadow Engine Failover](https://docs.nvidia.com/dynamo/dev/kubernetes-deployment/deployment-guide/shadow-engine-failover) - 来源:NVIDIA Dynamo 文档 > This is separate from Dynamo Snapshot. … It is not a hardware fault tolerance mechanism for GPU, node, or rack loss. … It does not preserve in-flight requests, network sockets, or KV cache state. ### [VergeOS Backup & DR](https://docs.verge.io/product-guide/backup-dr/overview/) - 来源:VergeOS Docs > Site Syncs - Offsite Replication … Incremental sync technology minimizes bandwidth usage … Automatic failover and failback capabilities … Combine local snapshots with remote replication ## 对卷宗的影响 - 18 家对照表:FT 锁步几乎仅 VMware;ZLR 未 GA;FusionCube/FusionOne 分列且后者 RPO 自称。 - AI 失败域写入 NVIDIA 层,不把 Snapshot 写成 HCI HA。 - SmartX 6.3 是今日国产可靠性主信号;Arcfra 海外 6.3 指标不得写入中国区表。